Syringe fill-finish manufacturing requirements for biologics | Vanrx
Pre-filled syringe manufactured on a syringe fill/finish machine from Vanrx Pharmasystems

Syringe fill-finish manufacturing requirements for today’s complex biologics

October 29, 2018 - Blog, Featured

Pharmaceutical companies are required to fill syringes with a variety of complex drug products. The challenges these companies are facing are based on the evolving characteristics of new complex therapeutics. 

Pre-filled syringes (PFS) are a well established drug delivery method for both new complex biologics and traditional small molecule drugs. PFS have many advantages over other container types including reduced medication errors, quick and safe preparation and administration, long shelf-lives, and reduced overfill — which in turn reduces batch volume and development cost. Pre-filled syringes may be easy to use, but add additional complexity to the fill-finish process.

The objective of this article is to focus on syringe fill-finish challenges pharmaceutical companies are experiencing with new complex biologics compared to small molecule drugs. These includes drug stability, plunger placement techniques, syringe and plunger formats, and the need for highly accurate syringe fill-finish machine for biologics. 

Traditional plunger placement

Many biologics are manufactured in small batches, quickly. The formulation of the biologics will affect the filling process. In order to avoid issues with drug stability and performance, syringe filling and stoppering requires precise plunger placement.

Traditional methods for syringe filling and stoppering use high-speed equipment to deliver the liquid product into the syringe and perform a stoppering technique called vented placement (slip stoppering). A plunger is placed inside a tube that is then inserted into the syringe body. As the tube is removed from the syringe, a rod will hold the plunger in place. The plunger will then expand to match the diameter of the syringe.

Note: This video does not show Vanrx’s stoppering process. It is included here to show the process of slip stoppering.

 

Increasingly, plungers intended for biologic drugs are manufactured with a coating that reduces interactions between the drug and plunger. This creates a disadvantage for slip stoppering as the compression forces applied can cause the coating to wrinkle or tear, resulting in closure leaks and contamination risk. Slip stoppering can also leave an air bubble (headspace) in the syringe between the drug product and plunger. When the syringe is exposed to reduced atmospheric pressure (e.g. during shipping), the air bubble can increase the possibility of plunger movement and potentially pull contaminants into the product. The oxygen in the headspace may also react with some oxygen-sensitive biologics affecting their stability and shelf-life.

Precise bubble-free plunger placement

Although traditional slip stoppering is a common practise, it is unfavourable for pharmaceutical companies manufacturing complex biologics. These companies either need to reduce the headspace by a bubble-free filling method or reconstitute the headspace with a non-oxygen environment by inert-gas back-fill.

Bubble-free filling accuracy is accomplished by an alternative stoppering technique called vacuum placement. To reduce the air bubble, a vacuum is pulled in each syringe, which causes a differential pressure. This pressure will draw the plunger into the syringe. Vacuum placement does not compress the plungers and leaves minimal headspace between the drug product and plunger. This method eliminates many challenges observed in slip-stoppering and is also preferred for high viscosity biologics such as ophthalmic medicines. The main issue with this established technology is the difficulty surrounding delivery of reliable and consistent levels of vacuum with in the limited amount of time available for the stoppering process. However, machines with mechanical assist and increased control over vacuum levels overcome this obstacle. 

The advantages of syringe bubble-free filling for biologics include: 

  • Dosing accuracy: with the removal of the air bubble, syringe orientation does not effect the dosage delivery to patient. 
  • Sterility assurance: decrease the likelihood of plunger movement during shipping and maintain the sterile environment within the syringe. 
  • Biologic stability: impede the ability for molecular rearrangements that result in protein aggregation, resulting in the stability of oxygen-sensitive drugs being maintained. 

Traditional vibratory bowls vs. ready-to-use nested format

In traditional fill-finish processes vibratory bowls are used to attain proper orientation of plungers and closures. This requires stringent control over the aseptic process as there are many opportunities for complications to arise. Vibratory bowls introduce particle generation from movement of the bowl itself and the plungers within it. Operator intervention is unavoidable in these systems due to fallen plungers and mandatory vibratory bowl cleaning to reduce, but not eliminate, particles created. This intervention significantly reduces throughput and reduces the sterility assurance of any drug product. 

To avoid these challenges, most PFS and corresponding plungers are supplied in a ready-to-use (RTU) nest and tub format. RTU nests are delivered ready for the filling process, as the sterilization process has already been completed. This system guarantees no glass-to-glass contact, requires no operator intervention due to fallen syringes, has no indirect product contact parts, and dramatically reduced particles are generation as vibratory bowls not used. Pharmaceutical companies require greater certainty in the performance and compatibility of components. RTU components give them this assurance. With greater certainty, new products or added production capacity can reach the market faster. 

Robotics in pharmaceutical manufacturing are used by Vanrx for aseptic processing of injectables into vials, syringes and cartridges. Robots are a key enabler of gloveless isolators. Can be used for syringe fill-finish manufacturing.

Auto-injectors 

Auto-injectors are medical devices used for a patient to self-deliver a dose of a particular medication. Some auto-injectors use PFS instead of cartridges. In this case the precise placement of the stopper is key. This delivery mechanism is in high demand for use by patients with diseases that effect dexterity and the ability to administer medication with a traditional syringe (e multiple sclerosis and rheumatoid arthritis). The manufacturing process for PFS used in auto injectors requires a high degree of accuracy and control to create a dependable drug delivery mechanism.

Flexible syringe fill-finish machine

Pharmaceutical companies need an aseptic filling machine they can depend on. This machine needs to provide complete control over the process via precise filling accuracy, stopper placement, vacuum control, and inert gas backfill. The Vanrx SA25 Aseptic Filling Workcell encompasses all these necessities and provides increased sterility assurance. link 

The SA25 is a gloveless robotic isolator in which the filling and closing process is performed robotically. The standard design allows for the flexibility to change between many nested ready-to-use syringe formats, as well as vials and cartridges. The syringes are filled with the desired drug by way of a recipe-driven control system that enables a repeatable aseptic filling process. Once the fill is completed, the plungers are placed extremely accurately through a combination of mechanical placement and precise vacuum control. This method reduces and can eliminate air bubbles inside the syringe, which ensures stability for all drug products. For oxygen sensitive drugs, an inert gas backfill mechanism can be utilized. The entire production process is predictable and regulated, even when filling and stoppering complex drug products.

Simple and flexible processing formats make syringes easier to incorporate into a pharmaceutical companies manufacturing line. Vanrx has partnered with leading pharmaceutical packaging suppliers to help our customers bring drug products to market faster. The Matrix Alliance partnerships for ready-to-use tub format of pre-sterilized syringes to integrate flawlessly to the aseptic-filling process. The Matrix Alliance is formed by ARaymondlife, Daikyo Seiko, Datwyler Group, Ompi, Schott AG, Schott Kaisha, and SiO2 Medical Products. Vanrx’s SA25 also has proven compatibility with BD syringes. 

 

Conclusion

Syringes are an indispensable drug delivery method and perform optimally when filled by an industry leading aseptic filling system. Contact Vanrx for more information about our syringe fill-finish machine, the SA25 Aseptic Filling Workcell.